Differential Pressure Switch
1.Differential Pressure Switch(SC-08)
SC-08 Differential pressure switch is capable to sense tiny pressure change and widely used to control the flue of aerator, to monitor fan and air conditioner. It is also suitable for over heating protection and frost protection in industrial cooling system. Due to its outstanding design, the setpoint can be adjust visually. Specification SC-08.zip Model SC-08 Media Air, non-combustible and non-aggressive gasses Max Operating Pressure 5 kPa Mounting position Diaphragm in any vertical plane Degree of protection IP54 (with cover) Operating Temperature -40? C to 85? C Contact Arrangement SPST or SPDT Electrical Rating Resistance: Initial: <400 milliohms; 1.5A (0.4A) @ 250V Terminals 6.4 mm(0.25") copper alloy Connection 6.0mm Dia. for tube connection Model Pressure Range Differential Tolerance SC-08A 20 ~ 200 Pa 10 Pa +/-15% SC-08B 30 ~300 Pa 10 Pa +/-15% SC-08C 40 ~400 Pa 20 Pa +/-15% SC-08D 50 ~ 500 Pa 20 Pa +/-15% SC-08E 200 ~ 1000 Pa 100 Pa +/-15% SC-08F 500 ~ 2500 Pa 150 Pa +/-15% Conversion: 1"W.C.= 1 inch/H2O=249Pa 1mbar=100Pa
Category:-> Differential Pressure Switch
2.Gas Pressure Switch(SC-09)
SC-09 Gas Pressure Switch is used to detect the pressure of city gas,natural gas,LPG and air etc. When the gas pressure changes,the diaphragm of the pressure receiving part detects it and operates the SPDT switch to ON/OFF control of the external electrical circuit. These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner. Model Operation pressure range (mbar) Differential (mbar) Max. Working Pressure(mbar) SC-09A 2..12 <2 300 SC-09B 10..50 <10 300 SC-09C 30..140 <20 300
Category:-> Differential Pressure Switch
Tags:Gas Pressure Switch Pressure Switch Differential Pressure switch
3.Pressure Switch(SC-61)
SC-61 differential switches are used in general industrial and marine sectors. The SC-61 differential pressure switches series consist of a variety of switches for applications in which safety or economical consequences are critical factors.
Category:-> Pressure Switch
4.Differential Pressure Switch (SC-07)
The type SC-07 pressure switch is used as a Differential pressure switchin ventilation ducts for the control of filters and fans, and inprimary and secondary control systems for the control of airdampers. The SC-07 pressure switches are alsoideally suited to protect heating coils from overheating andfor monitoring industrial air cooling circuits. Medium: air andnon-corrosive gases. Model SC-07 Media Air,non-combustible and non-aggressive gases Pressure Range 20-400Pa(Custom) Differential Range 8-50Pa(Custom) Max Operating Pressure 1.5kPa Mounting Position Diaphragm in any vertical Plane Operating Temperature -25ꇦ to +85ꇦ Contact Arrangement SPDT Electrical Rating Resisitance: initaial:?5 0milliohms Current: 1 A( 0 . 5 A) / 2 5 0 V Termimnals 6.4mm or 4.8 blade Connection OD 6.0mm for tube connection
Category:-> Differential Pressure Switch
5.Differential Pressure Switche(SC-03)
SC-03 can be is applied to detection positive or negative pressure. It can be used as a gauge or differential pressure switch with almost no hysteresis. If 2 switch points are required, 2 pressure switches with different calibrations should be employed. The method of fixing the tab terminals to the switch body does not allow for absolute air sealing. The switch is therefore not recommended for applications where static vacuum has to be maintained. However, special models with additional pressure spring which allow for the vacuum to be connected to the pressure inlet side are available on request.
Category:-> Differential Pressure Switch
Tags:auto oil pressure switch car oil pressure switch low pressure switch pressure sensor air pressure switch

Tel:86-577-62706263,86-15158479670
Fax:86-577-56848029
Email:sale@cnsencon.com
MSN: cnsencon@hotmail.com